if you have any question? Call Us 0086-371-60922096
if you have any question? Call Us 0086-371-60922096
for the turbine/generator range from approximately $670/kW to $1,140/kW, with costs on a per kW basis declining as capacity increases. The turbine/generator costs in Table 3 include the steam turbine, generator, and generator control system. The costs do not include the boiler, steam loop, and controls. Non-fuel O&M costs range
Get a Quoteturbines, a heat recovery boiler, a steam turbine and a diesel generator and produces u p to 60 MW power. More than a thousand units for 400 naval ships and …
Get a QuoteUse in steam boiler to drive a steam turbo-generator Ye s, by selecting most appropriate turbine and condenser . option. Trigeneration possible. Lower 75% 99% 75% 30% 16.7% Lower 418 kW …
Get a QuoteThe information herewith describes the packaged equipment for a coal-fired steam power plant with the output capacity of 15 MW. Essentially, the package consists of three main components of power generating equipment; namely the boiler, steam turbine and generator; plus some auxiliary devices associated wit these main operating components.
Get a QuoteWe continue to improve our technology and management level, provide customers with caring, trustworthy, rigorous, all-round services, and offer the most reliable Brushless Excitation Generator, Waste Heat Boiler, Biomass Power Plant EPC Solution to them. Innovation is the inexhaustible power and source of the company's continuous growth, the inevitable …
Get a QuoteIf your facility is operating a steam boiler at a higher pressure than you need for your process, a steam turbine generator might save you hundreds of thousands of dollars on your electric bill. AirClean's Indy STG is a modular, easy to install unit that provides an effective means to letdown your steam pressure through the turbine to
Get a Quote300kw electric steam boiler shanghai Agent. China Steam Turbine Generator, Steam Turbine Generator. Agent to join in. Shanghai SME 540KW-1600KW generator set. Mercedes-Benz 220KW-2400KW Get A Quote
Get a QuoteThe corresponding representation of ideal reheating process on T-s and h-s chart are shown in Fig. 2.16 (a) and (b). Refer to Fig. 2.16, (a). 5–1 shows the formation of steam in the boiler. The steam as at state point 1 (i.e., pressure p1 and temperature T1) enters the turbine and expands isentropically to a certain pressure p2 and
Get a Quotesteam for process loads. The boiler oper-ates at rated capacity for 6,000 hours per year (hr/yr). The boiler has reached the end of its service life, and the company is considering replacing the boiler with a new 100-psig boiler or with a high-pres-sure 600-psig boiler and a backpressure steam turbine-generator. Both new boiler
Get a QuoteA steam driven 750 KW turbo generator has a rated speed of 1200 RPM. The over speed setting for this unit must not exceed _____. A steam plant is operating at power when the atmospheric drain tank runs dry allowing a large air leakage into the main condenser.
Get a Quote2 numbers of 1100 kW AC motors for fiber. The two high capacities pressure boilers and a 30MW turbine were installed in place of the old boilers and smaller turbine. While selecting the turbo generator, it was decided to have the provision for operation of the co-generation plant, during th e off-season also. This could
Get a QuotePower requirement will be met from the DG sets of 3000 KW capacity. Approximately 3.5 KLPD of HSD will be used for the DG Set. Steam Turbo Generator. 1 X 20 MW. NEW. 12. Air Comp. BXP. 2 X 6500 nm3/h. NEW. 13. N2 Plant. PMC to finalise The spent wash will be concentrated in the MEE and incinerated in the Boiler. The steam generated from
Get a Quotepressure boiler boiler system) system) The two high capacities pressure boilers and a 30MW turbine were installed in place of the old boilers and Bagasse quantity TPH 1.0 1.0 smaller turbine. While selecting the turbo generator, it was decided to have the provision for operation of the Steam quantity TPH 2.1 2.2 co-generation plant, during the
Get a QuoteIn the power plant investigated which has a total of 14 engines, only eight engines are equipped with 750 kW waste heat recovery boilers for the purpose …
Get a QuoteTurbo generator – Wikipedia. steam turbo generator set 500W/24V for a steam locomotive: alternator (left) + turbine (right). A turbo generator set or turbine generator set is the compound of a steam turbine or gas turbine . Ask Price View More; Alternator – Wikipedia
Get a Quoteplant will be six steam driers, each of 17,200 square feet heating surface, three twin 10-inch presses, two three-stamp presses of a new type to make very small "block" or "dice" briquettes, and a boiler plant to produce 180,000 lbs. of steam per hour at a pressure of 615 lb. absolute and a temperature of 750° F.
Get a QuoteThe main and auxiliary air ejectors, the high and low pressure gland seals, the turbo gen gland seal, the boiler smothering steam, the steam whistle, the auxiliary contaminated evaporator steam, Aqua-Chem air ejectors, Nyrex feedwater heater, and the 150-35 psi reducing station in …
Get a QuoteMar 06, 2014 · Each fire room contained a single D type boiler which produced superheated steam at a pressure of 450 PSI and a temperature of 750° F. Each engine room contained one main propulsion generator rated at 4600 kW, 2700 VAC, 93.3 Hz, 5400 RPM, one ship service turbo generator rated at 300 kW at 450 VAC/40 kW DC, and a 6000 SHP, 400 RPM main
Get a QuoteSteam Generator OR Steam Boiler? - Process Heating
Get a QuoteA steam driven 750 KW turbo generator has a rated speed of 1200 RPM. The overspeed setting for this unit must not exceed . boiler steam pressure: while ensuring an adequate supply of oil with the hand or standby pump as the generator idles to a stop or drops below 3 psi . ensure the standby lube oil pump, if so equipped, is properly
Get a Quote4.5.2.2 Boilers. Steam turbines differ from reciprocating engines and gas turbines in that the fuel is burned in a boiler that is separate from the power generation equipment, the steam turbo-generator. The energy is transferred from the boiler to the turbine by an intermediate medium, steam under pressure.
Get a QuoteElectric Steam Generator Steam 6 Kw Electric Steam Generator With Super High Efficiency. Ready to Ship. $4,000 Automatic Steam Generator 36kw 72kw 108kw 144kw 216kw Vertical Fast Heating Machine Manufacturer Mini Electric Steam Boiler Steam Generator Price Boiler. $2,000.00 / Set. 1 Set (Min $750.00-$2,800.00 / Set. 1.0 Sets (Min. Order
Get a QuoteMar 08, 2019 · Boiler Ratings and Boiler Load – Alken-Murray, Innovative Pollution Solutions since 1934 Boiler Ratings and Boiler Load The oldest method of rating boilers, still used to rate small boilers, is by horsepower (hp). One horsepower is defined as the ability to evaporate 34.5 lbs of water into steam at 212 deg. F and above.
Get a Quoteof 250,000 lb. of steam per hr. at 660 lb. per sq. in. gage. Essentially then the new high pressure station CQn~ sists of one boiler and one high back pressure turbo-. generator, generating 6000 kw. of electrical energy and supplying some 230,000 lb. of steam at 200 lb. pressure to units 7 and 4 in the old plant. Before passing to
Get a QuoteBackground Over the years, many reports, tests, conferences, and case studies have been published on maintaining and upgrading boilers, steam turbine-generators, heat exchangers, and other major equipment items in fossil steam plants. In addition, applications of new technology have been demonstrated in operating plants around the world.
Get a Quote